Single-phase electronic multi-rate carrier energy meter
Single-phase electronic multi-rate carrier energy meter
DDSIF110a
0.0 0.0

The main technical parameters

model

DDSIF110

name Single-phase electronic multi-rate carrier energy meter
level of accuracy Level 1 Level 2

Dimensions (mm)

160 × 125 × 38

Rated voltage (V)

220

Basic current (A)

1.5 (6) 5 (30) 10 (40) 15 (60) 20 (80)

Starting current

0.4%Ib (Class 1.0)  0.5%Ib (Class 2.0)

Daily timing error   ≤0.5
Rated frequency (Hz)  50

 

main feature

1. Single-phase active energy measurement, remote centralized meter reading of power lines, with remote control power off function.
2. The software spread-spectrum method is used for power line carrier communication, which is accurate, reliable and strong in reading ability.
3. Electricity storage function: Daily zero-point electricity is automatically frozen.
4. Accurate active energy measurement, no need to adjust for long-term work.
5. Freeze settlement function, can save daily zero point and the most recent March electricity data.
6. Infrared programming, RS485 programming, power line carrier programming are optional.
7. The 48-hour hourly power freeze function of yesterday and today, with standby time slot and standby time switch function.
8. The hardware clock RX-8025 control scheme, the time and date cannot be set, and the time can only be corrected by broadcast commands.
9. The broadcast time correction does not require an answer. Only when the time difference between the calendar and clock of the slave station and the master station is within ± 5min, the time correction command is executed, and proofreading is only allowed once a day.
10. The information is displayed on LCD, with backlight function and power failure display function.

The main technical parameters

model

DDSIF110

name Single-phase electronic multi-rate carrier energy meter
level of accuracy Level 1 Level 2

Dimensions (mm)

160 × 125 × 38

Rated voltage (V)

220

Basic current (A)

1.5 (6) 5 (30) 10 (40) 15 (60) 20 (80)

Starting current

0.4%Ib (Class 1.0)  0.5%Ib (Class 2.0)

Daily timing error   ≤0.5
Rated frequency (Hz)  50

 

main feature

1. Single-phase active energy measurement, remote centralized meter reading of power lines, with remote control power off function.
2. The software spread-spectrum method is used for power line carrier communication, which is accurate, reliable and strong in reading ability.
3. Electricity storage function: Daily zero-point electricity is automatically frozen.
4. Accurate active energy measurement, no need to adjust for long-term work.
5. Freeze settlement function, can save daily zero point and the most recent March electricity data.
6. Infrared programming, RS485 programming, power line carrier programming are optional.
7. The 48-hour hourly power freeze function of yesterday and today, with standby time slot and standby time switch function.
8. The hardware clock RX-8025 control scheme, the time and date cannot be set, and the time can only be corrected by broadcast commands.
9. The broadcast time correction does not require an answer. Only when the time difference between the calendar and clock of the slave station and the master station is within ± 5min, the time correction command is executed, and proofreading is only allowed once a day.
10. The information is displayed on LCD, with backlight function and power failure display function.

Product description
Parameters
概要

 

Scan the QR code to read on your phone
We could not find any corresponding parameters, please add them to the properties table

National free consultation phone:

0755-26753428

Address: Comprehensive Building, Gaofa Science and Technology Park, Xili Longjing, Nanshan District, Shenzhen

Copyright© Shenzhen Jiangji Industrial Co., Ltd. 粤ICP备05044478号Powered by www.300.cn

江机实业